Replacing existing wall furnaces

Braemar wall furnaces are ideal for replacing existing wall furnaces, including the following models:

  • Braemar D11/D12/D45/D55
  • Vulcan Series 20/22/Quasar
  • IXL 10862
  • Convair Finesse Range

Important

  • The 30MJ/hr wall furnace is intended for domestic applications and replacement of older wall furnaces. Due to its higher thermal efficiency and improved air distribution, it is suitable for replacement of older 40MJ/hr models.
  • The 40MJ/hr wall furnace is suitable for heating very large areas and is not generally recommended for normal domestic applications due to higher air flow rates.
Please note: Additional kits may be required. Not suitable for direct replacement of fully-recessed models installed into double-brick walls.

INSTALLATION KIT REQUIREMENTS FOR COMMON WALL FURNACE REPLACEMENTS

Please note: when replacing existing Wall Furnaces with a WF25, a new coaxial flue system is required. Refer to flue kits required on the Flexible Installation Options chart.

Model being

Replaced

Flue adaptor kit 079981 (WF30/40)

Flue extension kit

079943 (WF30/40)

In-fill panel kit

085135 (WF25/30/40)

Requires coaxial flue kit WF25**

Braemar D11/12

Kit not required

Kit not required

Kit not required

Yes

Braemar D45/55

Kit not required

Kit not required

Yes *

Yes

Vulcan Series 20/22

Yes

Kit not required

Kit not required

Yes

Vulcan Quasar

Yes

Yes

Yes *

Yes

IXL 10862

Yes

Yes

Kit not required

Yes

Convair Finesse

Yes

Yes

Kit not required

Yes

* Required for inbuilt installations only
**Refer to Flexible Installation Options chart

 

Kit descriptions

  • Flue adaptor kit (079981):

The flue adaptor is used to connect between the flue spigot on the top of the Braemar WF30/40 and the bottom of the existing flue system to allow the WF30/40 to be installed at the correct height for some replacement installations, and to enable the use of the existing flue system (If the heater is replacing an existing unit it must be confirmed that the flue system complies with current requirements of AS/NZS5601 “Gas installations”).

  • Flue extension kit (079943):

The twin-skin flue extension is used in conjunction with the flue adaptor to connect between the flue spigot on the top of the Braemar WF30/40 and the bottom of the existing flue system to allow the WF30/40 to be installed at the correct height for some replacement installations, and to enable the use of the existing flue system (If the heater is replacing an existing unit it must be confirmed that the flue system complies with current requirements of AS/NZS5601 “Gas installations”).

  • In-fill panel kit (085135):

The in-fill panel kit is used to cover the existing wall opening or wall markings when replacing some older and taller heaters.

 